Alpha ECG-125 Manuel d'instructions Page 46

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 45
46
5. Oncethecorrectairgapisset,removethemanualheightadjustmentangeassembly.
While holding the adjust screw and adjust nut in place, turn the locking nut towards
the adjust nut until they meet.
6. Handtightenthemanualheightadjustmentangeassemblytolocktheadjustnutin
place on the adjust screw.
7. Withthemanualheightadjustmentangeadjustedcorrectly,youcanreinstallwith
thegrindingwheelandangenut.Fromthispoint,youcanfollowtheinstructionsfor
installing the grinding wheel.
Figure-46
Hold the Adjust
Screw and Adjust
Nut in place
Turn the Locking
Nut until it meets
the Adjust Nut
Adjust the Locking Nut
Vue de la page 45