Alpha Lectro 60V Spécifications Page 1

Naviguer en ligne ou télécharger Spécifications pour Unités d'alimentation électrique Alpha Lectro 60V. Alpha Lectro 60V Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - DSM Series

Technical ManualModel XP-EDH-AModel XP-EDHEffective: June 2006Alpha TechnologiesAlphaNet™ DSM SeriesExternal DOCSIS Transponder

Page 2 - Alpha Technologies

10745-838-B0-0012.0 InstallationBefore installing the XP-EDH-A into a power supply, review your system requirements and determine the number of cable

Page 3 - Technical Manual

11745-838-B0-0012.0 Installing the Transponder, continued2.1 General Installation for Supported Power Supplies, continued2.1.1 Mounting the Transpo

Page 4 - Table of Contents

12745-838-B0-0012.1.6 Confi rming the RF DropAn RF drop is required at the power supply site. The RF drop should not have plant voltage.The transponder

Page 5 - List of Figures and Tables

13745-838-B0-0012.1.10 Verifying OperationAfter the connections are complete and the transponder’s online LED is on solid, indicating network connecti

Page 6 - Safety Notes

14745-838-B0-0013.0 Installation Instructions for Specifi c Power SuppliesThese are specifi c installation instructions for standby power supplies supp

Page 7 - 1.0 Introduction

15745-838-B0-0013.0 Installation Instructions for Specifi c Power Supplies, continued3.1 Alpha XM2 Series, continuedFRONTONONPANELPOWERSUPPLYCHASSISJP

Page 8 - 1.1 System Overview

16745-838-B0-0013.0 Installation Instructions for Specifi c Power Supplies, continued3.1 Alpha XM2 Series, continued FRONTONONPANELPOWERSUPPLYCHASSIS

Page 9 - 1.3 MAC Address

17745-838-B0-0013.0 Installation Instructions for Specifi c Power Supplies, continued3.1 Alpha XM2 Series, continued 3.1.3 Connecting the XP-EDH-A t

Page 10 - 2.0 Installation

18745-838-B0-001NOTE:This alignment procedure requires that the output neutral of the power supply is connected to the chassis of the power supply. If

Page 11 - 2.1.2 Disconnecting DC Power

19745-838-B0-001If commercial power is present at the site, and the power supply is currently being powered by commercial AC line voltage, turn the ba

Page 12 - 2.1.8 Confi guring AM MIBS

PowerAlpha Technologies®

Page 13 - 2.1.10 Verifying Operation

20745-838-B0-0013.0 Installation Instructions for Specifi c Power Supplies, continued3.2 Alpha XM Series, continued 3.2.2 Connecting the XP-EDH-A to

Page 14 - 3.1 Alpha XM2 Series

21745-838-B0-0013.0 Installation Instructions for Specifi c Power Supplies, continued3.2 Alpha XM Series, continued 3.2.3 XM USM Output Voltage Cali

Page 15 - Alpha XM2 Series, continued

22745-838-B0-0013.3 Alpha AM/AP Series Power SupplyIf commercial power is present at the site, and the power supply is currently powered by commercia

Page 16 - 745-838-B0-001

23745-838-B0-0013.0 Installation Instructions for Specifi c Power Supplies, continued3.3 AM/AP Series Power Supply, continued 3.3.1 Connecting the X

Page 17 - USM2 power

24745-838-B0-0013.0 Installation Instructions for Specifi c Power Supplies, continued3.3 AM/AP Series, continued 3.3.2 AM/AP Series Output Voltage C

Page 18

25745-838-B0-0013.0 Installation Instructions for Specifi c Power Supplies, continued3.4 Alpha/Lectro ZTT+ Series Power SupplyThere are two forms of

Page 19

26745-838-B0-0013.0 Installation Instructions for Specifi c Power Supplies, continued3.4 Alpha/Lectro ZTT+ Series Power Supply, continued 3.4.2 Conn

Page 20 - CAUTION!

27745-838-B0-0013.0 Installation Instructions for Specifi c Power Supplies, continued3.4 Alpha/Lectro ZTT+ Series Power Supply, continued 3.4.3 Conn

Page 21

28745-838-B0-0013.0 Installation Instructions for Specifi c Power Supplies, continued3.4 Alpha/Lectro ZTT+ Series Power Supply, continued 3.4.4 Alph

Page 22

29745-838-B0-0014.0 Proprietary Management Information Bases (MIBs)You need to use two proprietary MIBs from AM Networks to successfully confi gure th

Page 23

AlphaNet™ DSM SeriesExternal DOCSIS TransponderModel XP-EDH-ATechnical Manual745-838-B0-001, Rev. AEffective Date: June 2006Copyright © 2006Alpha Tech

Page 24 - 3.3 AM/AP Series, continued

30745-838-B0-0015.0 Transponder Connector PinoutsConnector PinoutsPins numbered right to left, facing front panel, A = top row, B= bottom rowBattery

Page 25

31745-838-B0-0016.0 Cable Selection GuideXM , XM2 power suppliesInterface cables :CBL-PS-INTFC-01-003AM / AP power suppliesCBL-PS-INTRFC-01-002CBL-PS

Page 26

32745-838-B0-0016.0 Cable Selection Guide, continuedCBL-PS-BAT-06-004CBL-PS-BAT-06-0204FT20 FT2+241+241+12+V-V2+12CBL-PS-BAT-06-XXX4FT20 FTCBL-PS-BAT

Page 27 - 27745-838-B0-001

33745-838-B0-0016.0 Cable Selection Guide, continued220VACNEMA 6-15P220V USCBL-PS-PWR-04-001Lectro , 220VAC9VAC3FTCORDIEC C13XM , XM2 , AM/AP, 220VAC

Page 28 - Alpha/Lectro ZTT+ Series

34745-838-B0-0017.0 Dimensions and Specifi cations7.1 Dimensions of XP-EDH-APWRPower SupplyDSPowerONLINEUSOVERALLBatteriesTEMPORARY COVER FOR THREAD

Page 29

35745-838-B0-0017.0 Dimensions and Specifi cations, continued7.2 Battery Cable Wiring Diagram1+24VBATTERY CABLECBL-PS-BAT-06-004BLACKREDBROWNWIREGREE

Page 30

36745-838-B0-0018.0 Specifi cationsGeneral SpecificationsGeneralModel: XP-EDH-APower Supplies Supported: XM2 (requires USM2 or USM2.5)XM (requires USM)L

Page 31 - 6.0 Cable Selection Guide

Due to continuing product improvements, Alpha reserves the right to change specifi cations without notice. Copyright © 2006 Alpha Technologies, Inc. Al

Page 32 - CBL-PS-BAT-12-020

4745-838-B0-001Table of ContentsSafety Notes ...

Page 33 - Line Voltage Cables:

5745-838-B0-001List of Figures and TablesFig. 1-1, AlphaNet DSM Series Model XP-EDH-A External DOCSIS Status Monitor Front Panel ...

Page 34 - 7.1 Dimensions of XP-EDH-A

6745-838-B0-001Safety NotesReview the drawings and illustrations contained in this manual before proceeding. If there are any questions regarding the

Page 35 - STRING 1

7745-838-B0-0011.0 IntroductionThe AlphaNet DSM Series Model XP-EDH-A External DOCSIS Transponder manages network powering through the existing cable

Page 36 - 8.0 Specifi cations

8745-838-B0-0011.0 Introduction, continued1.1 System OverviewThe XP-EDH-A is designed for use with the following standby power supplies:XM2XMAM/APZTT,

Page 37

9745-838-B0-0011.0 Introduction to the DOCSIS Transponder, continued1.2 LED IndicatorsThe XP-EDH-A contains a DOCSIS 1.1 cable modem. The front panel

Commentaires sur ces manuels

Pas de commentaire